Electrodepot 40 Amp 12 Pole (4 Pole x 3) Normally Open, 110-120VAC Coil (Silent Operation), Motor Load 40A and Lighting Load 63A Contactor Bundle with 8\ DIN Rail and 2 Number 10 Screws
BUNDLE CONTENT: 6 ITEMS – Three (3) 40A 4 Pole Normally Open (NO) Contactors with power status indicator.
one (1) compatible Slotted Steel Zinc Plated 35mm x 200mm DIN Rail and two (2) stainless steel truss head screws (#10, 1/2") for immediate home or industrial installation.
CONTACTOR APPLICATIONS – Lighting, motor or switching. AC-1 for resistance furnaces, incandescent lamps or electric heaters.
and AC-3 for air conditioners, compressors or fans. 24/120/220/277 V, with an energy saving, silent and no humming coil.
COIL VOLTAGE AND LOAD – Contactor IEC 400V. Coil Voltage 110/120VAC, 50/60 Hz.
OTHER CONTACTOR DETAILS – Contactor type NO with 4 poles, power status indicator. IEC AC Rate: AC-1.
8 kW. Electric e strength: 4 kV. Operating Temperature -30…+70 °C (-22…+158 °F). Dimensions (approx.): 54 x 64 x 84 mm / 2.1'' x 2.5'' x 3.3'' (Length x Width x Height).
DIN RAIL – Standard mounting support for any electromechanical component, including contactors, using the DIN specificat....
Electrodepot 40 Amp 8 Pole (4 Pole x 2) Normally Open, 110/120VAC Coil (Silent Operation), Motor Load 40A and Lighting Load 63A Contactor Bundle with DIN Rail, 35 x 150 mm and 2#10 Screws
BUNDLE CONTENT: 5 ITEMS – Two (2) 40A 4 Pole Normally Open (NO) Contactors with power status indicator.
one (1) compatible Slotted Steel Zinc Plated 35mm x 150mm DIN Rail and two (2) stainless steel truss head screws (#10, 1/2") for immediate home or industrial installation.
CONTACTOR APPLICATIONS – Lighting, motor or switching. AC-1 for resistance furnaces, incandescent lamps or electric heaters.
and AC-3 for air conditioners, compressors or fans. 24/120/220/277 V, with an energy saving, silent and no humming coil.
COIL VOLTAGE AND LOAD – Contactor IEC 400V. Coil Voltage 110/120VAC, 50/60 Hz.
OTHER CONTACTOR DETAILS – Contactor type NO with 4 poles, power status indicator. IEC AC Rate: AC-1.
8 kW. Electric e strength: 4 kV. Operating Temperature -30…+70 °C (-22…+158 °F). Dimensions (approx.): 54 x 64 x 84 mm / 2.1'' x 2.5'' x 3.3'' (Length x Width x Height).
DIN RAIL – Standard mounting support for any electromechanical component, including contactors, using the DIN specificatio....
Elecnova SFB1-63HC 1P Miniature Circuit Breakers DIN-Rail Mounted MCB 50/60Hz Current of 40Amp Voltage 400V Overload, Thermal Magnetic Trip Short-Circuit Protection of Lighting
SIZE: 2.9"x 3.2"x 0.7"/ 75 x81 x 18mm (L*W*H). Fit for 35mm DIN rail..
FUNCTION:It is used for overload and short circuit protection in the line with current up to 63A, and it can also be used for infrequent switching of electrical devices and lighting circuits under normal conditions..
EASY INSTALLATION: Modular sturcture, can be easily installed on the DIN standard guide rail in distribution box, bistable locking clip..
APPLICATIONS: SFB1-63 series miniature circuit breaker is mainly used for overload and short-circuit protection of lighting, power distribution lines and equipment in office buildings, residences and similar buildings..
SFB1-63HC 2P Miniature Circuit Breakers DIN-Rail Mounted MCB AC 50/60Hz Current of 10Amp Voltage 400V Overload, Thermal Magnetic Trip Short-Circuit Protection of Lighting
SIZE: 2.9"x 3.2"x 1.4"/ 75 x81 x 36mm (L*W*H). Fit for 35mm DIN rail..
FUNCTION:It is used for overload and short circuit protection in the line with current up to 63A, and it can also be used for infrequent switching of electrical devices and lighting circuits under normal conditions..
EASY INSTALLATION: Modular sturcture, can be easily installed on the DIN standard guide rail in distribution box, bistable locking clip..
APPLICATIONS: SFB1-63 series miniature circuit breaker is mainly used for overload and short-circuit protection of lighting, power distribution lines and equipment in office buildings, residences and similar buildings..
SFB1-63HC 3P Miniature Circuit Breakers DIN-Rail Mounted MCB AC 50/60Hz Current of 63Amp Voltage 400V Overload, Thermal Magnetic Trip Short-Circuit Protection of Lighting
SIZE: 2.9"x 3.2"x 2.13"/ 75 x81 x 54mm (L*W*H). Fit for 35mm DIN rail..
FUNCTION:It is used for overload and short circuit protection in the line with current up to 63A, and it can also be used for infrequent switching of electrical devices and lighting circuits under normal conditions..
EASY INSTALLATION: Modular sturcture, can be easily installed on the DIN standard guide rail in distribution box, bistable locking clip..
APPLICATIONS: SFB1-63 series miniature circuit breaker is mainly used for overload and short-circuit protection of lighting, power distribution lines and equipment in office buildings, residences and similar buildings..
SFB1-63HC 3P Miniature Circuit Breakers DIN-Rail Mounted MCB AC 50/60Hz Current of 16Amp Voltage 400V Overload, Thermal Magnetic Trip Short-Circuit Protection of Lighting
SIZE: 2.9"x 3.2"x 2.13"/ 75 x81 x 54mm (L*W*H). Fit for 35mm DIN rail..
FUNCTION:It is used for overload and short circuit protection in the line with current up to 63A, and it can also be used for infrequent switching of electrical devices and lighting circuits under normal conditions..
EASY INSTALLATION: Modular sturcture, can be easily installed on the DIN standard guide rail in distribution box, bistable locking clip..
APPLICATIONS: SFB1-63 series miniature circuit breaker is mainly used for overload and short-circuit protection of lighting, power distribution lines and equipment in office buildings, residences and similar buildings..
E-T-A Circuit Protection and Control 413-K14-LN2-40A, Circuit Breaker; Therm; Push/Pull; Cur-Rtg40A; Panel; 1 Pole; Vol-Rtg 28VDC
❶FUNCTION - This DZ47-63 C63 three-pole circuit breaker is a circuit breaker dedicated to 63Amp AC 50Hz power circuit for circuit security protection..
❷APPLICATION - DZ47-63 series miniature circuit breakers are suitable for residential building lighting distribution system (type C) or motor power distribution system (type D)..
❸INSTALLATION - The backside is a standard DIN rail installation, with track fixing buckle, can be easily installed on the DIN standard guide rail in distribution box, bistable locking clip, the installation more convenient..
❹CONSTRUCTION - With rapid arc extinguishing system and circuit protection electromagnetic trip device.
With thermoplastic shell, which is cured under heat or other environments or has the characteristics of insolubility and insulation..
❺AFTERSALES - Please feel free to let us know if you meet any product quality issue, we will try our best to help you..