Best Din Rail Enclosure

VictorsHome Miniature Circuit Breaker Low-Voltage DZ47-63 2 Pole 20A 400V DIN Rail Mount C20

  • Rated Voltage: 400V. Fit for 35mm DIN rail..
  • ☀MINI CIRCUIT BREAKER - Be used to protect a low-voltage electrical system from damage caused by excess current resulting from an overload or short circuit..
  • ☀FAST TRIP FUNCTION - Ensure reliable operation of the load and prolong the life of circuit breaker. It can also work as on-off switch for load circuits..
  • ☀EASY INSTALLATION - Modular sturcture, can be easily installed on the DIN standard guide rail in distribution box, bistable locking clip..
  • ☀APPLICATIONS - DZ47-63 series miniature circuit breaker is mainly used for the illumination of office buildings and residential buildings. It is used for distribution and protection the facilities from damages caused by overload and short-circuit. If you have any question, please feel free to contact us !.
Check Stock

Zenna Home, Stainless Steel Rust-Resistant Over-The-Shower Door Caddy, 2-Shelf

  • QUALITY STAINLESS STEEL CONSTRUCTION: Protects against rust in your bath or shower.
  • IDEAL STORAGE SOLUTION FOR SHOWERS WITH GLASS/DOOR ENCLOSURES: Caddy easily mounts on door rail, with no tools needed.
  • ROOM FOR ALL YOUR SHOWER ESSENTIALS: Caddy includes 2 large storage baskets, soap dish and holders for razors, washcloths and shower poufs.
  • YOUR BATH ITEMS STAY DRY: Installation on shower door rail keeps bath products out of the way of your shower.
  • FITS ON ANY STANDARD SHOWER DOOR ENCLOSURE: Use caddy on any enclosure with a door up to 2.5 inches thick.
  • includes suction cups to keep caddy firmly against shower door.
Check Stock

Electrodepot 40 Amp 4 Pole Normally Closed Contactor, 110-120V Coil, Motor Load 20A, Lighting 40A Bundle with Slotted Steel Zinc Plated DIN Rail, 35 mm x 6 in – 1 Piece with 2 Number 10 Screws

  • BUNDLE CONTENT: 4 ITEMS – One (1) 40A Contactor, one (1) compatible Slotted Steel Zinc Plated DIN Rail and two (2) drive stainless steel truss head screws (#10, 1/2") for immediate installation.
  • APPLICATIONS – Lighting, motor or switching. AC-1 for resistance furnaces, incandescent lamps or electric heaters.
  • and AC-3 for air conditioners, compressors or fans. 24/120/220/277 V, with an energy saving, silent and no humming coil.
  • COIL VOLTAGE AND LOAD – Contactor IEC 400V. Coil Voltage 110/120VAC, 50/60 Hz.
  • Coil load Inrush 30VA, Sealed 4VA. Inductive/Motor Load: 20Amp, Resistive/Incandescent Load: 40Amp. DC Load: 30Amp @ 24VDC. Compatible with 20 Amp, 30 Amp, 32 Amp and 40 Amp loads. Power Lug Terminal Capacity AWG # 4.
  • OTHER CONTACTOR DETAILS – Contactor type NC with 4 poles, power status indicator. IEC AC Rate: AC-1.
  • 8 kW. Electric e strength: 4 kV. Operating Temperature -30…+70 °C (-22…+158 °F). Dimensions (approx.): 85 x 45 x 92 mm / 3.4'' x 1.7'' x 3.6'' (Length x Width x Height).
  • DIN RAIL – Standard mounting support for any electromechanical component, including contactors, using the DIN specifications adopted by European (EN) and international (IEC) standards. Standard width 34.9mm (1.375”) length 152.40mm (6”) and t....
Check Stock

Electrodepot 40 Amp 12 Pole (4 Pole x 3) Normally Open, 110-120VAC Coil (Silent Operation), Motor Load 40A and Lighting Load 63A Contactor Bundle with 8\ DIN Rail and 2 Number 10 Screws

  • BUNDLE CONTENT: 6 ITEMS – Three (3) 40A 4 Pole Normally Open (NO) Contactors with power status indicator.
  • one (1) compatible Slotted Steel Zinc Plated 35mm x 200mm DIN Rail and two (2) stainless steel truss head screws (#10, 1/2") for immediate home or industrial installation.
  • CONTACTOR APPLICATIONS – Lighting, motor or switching. AC-1 for resistance furnaces, incandescent lamps or electric heaters.
  • and AC-3 for air conditioners, compressors or fans. 24/120/220/277 V, with an energy saving, silent and no humming coil.
  • COIL VOLTAGE AND LOAD – Contactor IEC 400V. Coil Voltage 110/120VAC, 50/60 Hz.
  • Coil load Inrush 52VA, Sealed 10VA. Inductive/Motor Load: 40Amp, Resistive/Incandescent Load: 63Amp. DC Load: 30Amp @ 24VDC. Compatible with 15 Amp, 20 Amp, 30 Amp, 32 Amp, 40 Amp, 50 Amp, 60 Amp and 63 Amp loads. Power Lug Terminal Capacity AWG # 4.
  • OTHER CONTACTOR DETAILS – Contactor type NO with 4 poles, power status indicator. IEC AC Rate: AC-1.
  • 8 kW. Electric e strength: 4 kV. Operating Temperature -30…+70 °C (-22…+158 °F). Dimensions (approx.): 54 x 64 x 84 mm / 2.1'' x 2.5'' x 3.3'' (Length x Width x Height).
  • DIN RAIL – Standard mounting support for any electromechanical component, including contactors, using the DIN specificat....
Check Stock

Bounce Pro Replacement Top Rail with Leg sockets for The 14 Flex Models

  • NEVER USED / OPEN BOX Replacement 14FT Top Rail with Socket.
  • Six Top Rail with Sockets needed to complete trampoline.
  • Each top rail holds 6 springs (SPRINGS NOT INCLUDED).
  • Key Number: 3 in Manual for Trampoline and Enclosure Parts.
  • Fits models: All 14' Flex Models, TR-14-63a, TR-16803ES-WMC, 5F60753.
Check Stock

Electrodepot 40 Amp 8 Pole (4 Pole x 2) Normally Open, 110/120VAC Coil (Silent Operation), Motor Load 40A and Lighting Load 63A Contactor Bundle with DIN Rail, 35 x 150 mm and 2#10 Screws

  • BUNDLE CONTENT: 5 ITEMS – Two (2) 40A 4 Pole Normally Open (NO) Contactors with power status indicator.
  • one (1) compatible Slotted Steel Zinc Plated 35mm x 150mm DIN Rail and two (2) stainless steel truss head screws (#10, 1/2") for immediate home or industrial installation.
  • CONTACTOR APPLICATIONS – Lighting, motor or switching. AC-1 for resistance furnaces, incandescent lamps or electric heaters.
  • and AC-3 for air conditioners, compressors or fans. 24/120/220/277 V, with an energy saving, silent and no humming coil.
  • COIL VOLTAGE AND LOAD – Contactor IEC 400V. Coil Voltage 110/120VAC, 50/60 Hz.
  • Coil load Inrush 52VA, Sealed 10VA. Inductive/Motor Load: 40Amp, Resistive/Incandescent Load: 63Amp. DC Load: 30Amp @ 24VDC. Compatible with 15 Amp, 20 Amp, 30 Amp, 32 Amp, 40 Amp, 50 Amp, 60 Amp and 63 Amp loads. Power Lug Terminal Capacity AWG # 4.
  • OTHER CONTACTOR DETAILS – Contactor type NO with 4 poles, power status indicator. IEC AC Rate: AC-1.
  • 8 kW. Electric e strength: 4 kV. Operating Temperature -30…+70 °C (-22…+158 °F). Dimensions (approx.): 54 x 64 x 84 mm / 2.1'' x 2.5'' x 3.3'' (Length x Width x Height).
  • DIN RAIL – Standard mounting support for any electromechanical component, including contactors, using the DIN specificatio....
Check Stock

Elecnova SFB1-63HC 1P Miniature Circuit Breakers DIN-Rail Mounted MCB 50/60Hz Current of 40Amp Voltage 400V Overload, Thermal Magnetic Trip Short-Circuit Protection of Lighting

  • SIZE: 2.9"x 3.2"x 0.7"/ 75 x81 x 18mm (L*W*H). Fit for 35mm DIN rail..
  • FUNCTION:It is used for overload and short circuit protection in the line with current up to 63A, and it can also be used for infrequent switching of electrical devices and lighting circuits under normal conditions..
  • EASY INSTALLATION: Modular sturcture, can be easily installed on the DIN standard guide rail in distribution box, bistable locking clip..
  • APPLICATIONS: SFB1-63 series miniature circuit breaker is mainly used for overload and short-circuit protection of lighting, power distribution lines and equipment in office buildings, residences and similar buildings..
Check Stock

SFB1-63HC 2P Miniature Circuit Breakers DIN-Rail Mounted MCB AC 50/60Hz Current of 10Amp Voltage 400V Overload, Thermal Magnetic Trip Short-Circuit Protection of Lighting

  • SIZE: 2.9"x 3.2"x 1.4"/ 75 x81 x 36mm (L*W*H). Fit for 35mm DIN rail..
  • FUNCTION:It is used for overload and short circuit protection in the line with current up to 63A, and it can also be used for infrequent switching of electrical devices and lighting circuits under normal conditions..
  • EASY INSTALLATION: Modular sturcture, can be easily installed on the DIN standard guide rail in distribution box, bistable locking clip..
  • APPLICATIONS: SFB1-63 series miniature circuit breaker is mainly used for overload and short-circuit protection of lighting, power distribution lines and equipment in office buildings, residences and similar buildings..
Check Stock

1769-OA16 Compact Ac I/o Output Module in Stock New in Box 1 Year Warranty

  • Taiwan DINKLE fireproof nylon material DIN rail mount carrier(not China low quality carrier), can support width 35mm, 32mm and 15mm rail..
  • Matching PCB Thickness 1.6mm to 2.0mm (recommended 2.0mm)..
Check Stock

SFB1-63HC 3P Miniature Circuit Breakers DIN-Rail Mounted MCB AC 50/60Hz Current of 63Amp Voltage 400V Overload, Thermal Magnetic Trip Short-Circuit Protection of Lighting

  • SIZE: 2.9"x 3.2"x 2.13"/ 75 x81 x 54mm (L*W*H). Fit for 35mm DIN rail..
  • FUNCTION:It is used for overload and short circuit protection in the line with current up to 63A, and it can also be used for infrequent switching of electrical devices and lighting circuits under normal conditions..
  • EASY INSTALLATION: Modular sturcture, can be easily installed on the DIN standard guide rail in distribution box, bistable locking clip..
  • APPLICATIONS: SFB1-63 series miniature circuit breaker is mainly used for overload and short-circuit protection of lighting, power distribution lines and equipment in office buildings, residences and similar buildings..
Check Stock