Thermocouple Thermometer Digital K Type Thermometer with 4 Thermocouples, -328~2500℉ Measuring Range HVAC Thermometer Dual Channels Temperature Meter Gauge with LED Backlight & ADJ Compensation
✅ 【Wide Measurement Range】The main unit measuring range is: -328~2501℉(-200~1372℃).
Range of K type thermocouple(Stainless Steel):-58~1292℉(-50~700°C).
Bead-type thermocouple(blue):-4~392℉(-20~200°C).
✅【Multi-Functional】: HD large screen display, ℉/℃ and K/J switchable, Max/Min/Average, Data Hold, Auto power-off function(can be cancelled manually).
✅【Differential Temperature】Long press T1-T2 or T2-T1, and find the difference temperature value between T1&T2 testing samples easily..
✅【Hi/Low Flash Alarm】Manually set the upper and lower alarm thresholds. The red backlight of the screen will flash when the testing value is higher or lower than the set thresholds..
✅【ADJ compensation】Long press Hi and Low button together, adjust the ADJ compensation value to complete the calibration procedure, ADJ compensation range: -9~9℃..
Fluke 568 Dual Infrared Thermometer, -40 to +1472 Degree F Range, Contact/Non Contact
Dual infrared and thermocouple thermometer for noncontact or contact temperature measurement in electrical maintenance and monitoring industrial and manufacturing processes.
Measures temperature with the infrared sensor from -40 to +800 degrees C (-40 to +1472 degrees F) with an accuracy of + or - 1 degree C (+ or - 2 degrees F).
Measures temperature with the included Type K bead thermocouple from -40 to +260 degrees C (-40 to +500 degrees F).
50:1 infrared distance-to-spot ratio with laser sighting for pinpointing the measurement area.
Stores up to 99 points of data for analysis and monitoring on a computer.
Automated RTD and Thermocouple Calibrator. Comes with rubber boot, hands free carrying case, test leads and NIST cert..
Easy to use With the PIE 525B you can check and calibrate all your thermocouple and RTD instruments and measure temperature sensors..
Take it into the shop, plant or field Carry it without worry - it comes protected with a rubber boot and rugged, low profile switches. Easy to operate even in the dark areas of the plant with the backlit display..
Calibrate thermocouple instruments to 0.1 & 0.01 degrees-F & degrees-C The PIE 525B works with the thermocouples you use including types J, K, T, E, R, S, B, N, G, C, D, L (J-DIN), U (T-DIN) and P (Platinel II). Or calibrate from -13.0000 to +80.0000 mV..
Calibrate RTD instruments to 0.1 & 0.01 degrees-F & degrees-C Stop carrying around a decade box and RTD resistance tables. The 525B works with the RTDs you use including Platinum 10, 50, 100, 200, 500 & 1000 Ohm (alpha = 3850), Platinum 100 Ohm (alpha = 3902, 3916, 3926), Copper 10 & 50 Ohm, and Nickel 120 Ohm. Or calibrate from 0.000 to 400.000 and 0.00 to 4000.00 Ohms..
FLUKE FLUKE-62 MAX+ INFRARED THERMOMETER, -30C to +650C / -22F to +1202F
Dual infrared and thermocouple thermometer for noncontact or contact temperature measurement in electrical maintenance and monitoring industrial and manufacturing processes.
Measures temperature with the infrared sensor from -40 to +800 degrees C (-40 to +1472 degrees F) with an accuracy of + or - 1 degree C (+ or - 2 degrees F).
Measures temperature with the included Type K bead thermocouple from -40 to +260 degrees C (-40 to +500 degrees F).
50:1 infrared distance-to-spot ratio with laser sighting for pinpointing the measurement area.
Stores up to 99 points of data for analysis and monitoring on a computer.
Supco EM60 Dual-Channel Differential Digital Thermocouple Thermometer with Probes, -200 to 1300 Degrees C, -328 to 2372 Degrees F, Accuracy of + or - 0.1% of reading + 0.7 Degree C
Digital thermometer with probes for applications requiring a broad range of temperature measurements, including superheat measurements, food service applications, and heating, ventilation, and air-conditioning system maintenance.
Measures temperature from -200 to 1300 degrees C (-328 to 2372 degrees F), with a best accuracy of + or - 0.1% of reading + 0.7 degree C (1.4 degrees F).
Accepts K-type thermocouple probes, for a broader temperature measurement range than a thermistor sensor, or J-type thermocouple probes, for higher accuracy than K-type sensor.
Dual-channel thermometer with two inputs for measuring the temperature of two samples at the same time.
Displays current temperature for either input channel, the highest or lowest temperature reading for a session, or the difference between the two channels.