CESARIAS K-Type Panel Mount Thermocouple Mini Plug Connector, Male and Female, Yellow…
Type: K Type Male Female Wire Connector Thermocouple Plug Adapter.
High Quality: Yellow plastic shell ensures good insulation, and 2 flat metal male pins construct ensures good contact..
Fine workmanship, stable performance, durable in use..
Function: Allow you to use the new thermocouples with olter thermometer or some multimeters for contact temperature measurement..
Purpose: Be widely used in thermocouple and RTD circuits, best solution for quick and good contact. Can be used with k type digital thermometer to measure temperature of air and gas..
CDN INTP662 Infrared Gun / Thermocouple Thermometer for Food. 1.5' Height, 2.15' width, 6.25' Length, White
Measurement range: infrared: -76 to +662°f/-60 to +350°c.
thermocouple: -76 to +662°f/-60 to +350°c, distance spot: 8:1, display size: 0.875 w x 1.125 h (in)/2.2 w x 2,85 h (cm).
Nsf certified, 1.5 mm thin tip, dual function with infrared for non-contact surface temperatures and thermocouple probe for internal temperatures.3.75 inch (9.53 cm) probe.
Data-hold, one-button operation, battery status indication, maximum, minimum and lock modes for continuous scanning.
Fluke 568 Dual Infrared Thermometer, -40 to +1472 Degree F Range, Contact/Non Contact
Dual infrared and thermocouple thermometer for noncontact or contact temperature measurement in electrical maintenance and monitoring industrial and manufacturing processes.
Measures temperature with the infrared sensor from -40 to +800 degrees C (-40 to +1472 degrees F) with an accuracy of + or - 1 degree C (+ or - 2 degrees F).
Measures temperature with the included Type K bead thermocouple from -40 to +260 degrees C (-40 to +500 degrees F).
50:1 infrared distance-to-spot ratio with laser sighting for pinpointing the measurement area.
Stores up to 99 points of data for analysis and monitoring on a computer.
Cooper EconoTemp 32311-K EconoTemp Thermocouple Thermometer, Type K, -40 to 500 Degrees F Temperature Range, Multicolor
Dual-range digital Type K thermocouple thermometer for use in monitoring temperatures of food products.
Measures temperature from -40 to +500 degrees F (-40 to +260 degrees C), with an accuracy of + or - 2 degrees F (1 degree C) at ambient temperatures 68 to 86 degrees F (20 to 30 degrees C).
Accepts standard Type K thermocouple probes (sold separately).
Molded rubber casing provides impact and water resistance.
CE mark indicates compliance with applicable EU directives, and NSF listing indicates compliance with applicable safety standards.
FLUKE FLUKE-62 MAX+ INFRARED THERMOMETER, -30C to +650C / -22F to +1202F
Dual infrared and thermocouple thermometer for noncontact or contact temperature measurement in electrical maintenance and monitoring industrial and manufacturing processes.
Measures temperature with the infrared sensor from -40 to +800 degrees C (-40 to +1472 degrees F) with an accuracy of + or - 1 degree C (+ or - 2 degrees F).
Measures temperature with the included Type K bead thermocouple from -40 to +260 degrees C (-40 to +500 degrees F).
50:1 infrared distance-to-spot ratio with laser sighting for pinpointing the measurement area.
Stores up to 99 points of data for analysis and monitoring on a computer.
Fluke 52-2 Dual Input Digital Thermometer, 3 AA Battery, -418 to 2501 Degree F Range, 60 Hz Noise Rejection
Thermocouple thermometer for use in applications requiring a broad range of temperatures, including furnaces, kilns, freezers, and other industrial applications.
Measures temperatures in Celsius, Fahrenheit, or Kelvin via a Type K, Type J, Type T, or Type E thermocouple probe.
Includes a Type K bead thermocouple probe with a 40" cable that measures from -40 to +260 degrees C (-40 to +500 degrees F).
Provides the relative time of minimum, maximum, and average temperature measurements for monitoring.
Conforms to NIST standards for compliance with regulations.
NEWREACH Thermocouple and Tilt Switch for Outdoor Patio Heater, Dump Switch for Propane Gas Patio Heater Pyramid Style Tower Heater Firesense Heater, Tilt Switch and Thermocouple Sensor Kit for Winter
This thermocouple and tilt switch kit is to fix the problem that the pilot light or flame does NOT stay lit, or the thermocouple is broken..
The safety dump switch will automatically stop the heater when it's tilted or dropped, prevent the occurrence of gas leakage when the fire is extinguished and the gas is still on, which is more secure..
Easy to install, just connect the probe to the ignition device, the thermocouple to the valve, and the other two ports to the safety dumping switch..
Works with propane gas patio heater, outdoor standing patio heater, pyramid-style tower heater, fire sense heater, dome-style heater, tabletop heater, Amazonbasics heater, Hampton Bay patio heater, Lowes patio heater, etc..
Thermocouple wire total 350mm with temperature resistance sleeves, with threaded M8*1 and M6. Suitable for weak dump switches with gas R ≤ 10mΩ. Please check the compatibility before purchasing this product..