Best Standard Thermocouple

Mastech MS6514 Dual Channel Digital Thermometer Temperature logger Tester USB Interface 1000 data

  • Apply to the J / K / T / E / R / S / N type thermocouple..
  • Thermocouple deviation to compensate for..
  • Automatic and manual storage Data(1000)..
Check Stock

MENSI Safety Thermocouple Sensor for Honeywell Tradeline Bryant Emerson Gas Furnace Fireplace Water Heater 36 Thermocoupler

  • This is a Brand New Replacement Gas Furnace Water Heater Thermocouple.
Check Stock

K Thermocouple Block Ceramic Insulator Kiln Probe 2372 F 11G High Temperature

  • Cable: 1m (3.3ft) Internal Insulation: Fiberglass.
  • Measuring Temperature: -58 to 2372 °F (-50 to 1300 ).
  • Its connector can be connected dierectly to Digital Thermometers..
  • The length of this thermocouple is measured by the number of 1 inch long ceramics..
Check Stock

Thermocouple Replacement for Bryant Gas Furnace Water Heater 24 Thermocouple P671-4242

  • This thermocouple Can be used on a variety of appliances in your home.
  • Works for both LP and natural gas applications.
  • Push-in clip, split nut, and adapter assembly for easy pilot installation.
Check Stock

generec Replacement QuadraFire Pellet Stove Thermocouple Ceramic Protection Cover 812-1322

  • QuadraFire Pellet Stove Thermocouple Ceramic Protection Cover 812-1322.
  • QuadraFire 800,1000,1100i, 1200,1200i,Thermocoup​le Ceramic Tube 812-1322.
  • QuadraFire Castile, Contour, Santa Fe, Mt Vernon (OE) Thermocoup​le Ceramic Tube.
  • Newest Style Thermocouple Replacement Protection Tube.
  • Measures 2 7/8" Length x 1/2" Width - *NO Returns on Thermocouples*.
Check Stock

MYPIN® Universal Digital TA6-SNR PID Temperature Controller with Relay DIN 1/8 SSR-25DA and K type thermocouple,Dual Display for F/C,7 Output Combinations,Accuracy 0.2%

  • √ ● Dual display for Fahrenheit(F) and Celsius(C),Range: -1999 to 9999 (depends on the input signal).
  • √ ● Input: Thermo Resistor: PT100, Cu50,Thermocouple: K,Wre3 ~ Wre25 , Main Output: SSR: Open circuit: 4V, Closed Circuit: 24V 40mA DC.
  • √ ● K type thermocouple Temperature rang:0-800℃, Sensor Dia: 4.5mm, Cable Length: 2m.
  • √ ● Solid state relay SSR-25DA Load Voltage: AC 24-380V, Load Current: 25A, Input Voltage: DC 3-32V.
  • √ ● Packing details: 1 x SNR Temperature Controller( DIN 1/8), 1 x SSR-25DA Solid State Relay, 1 x K Type Thermocouple( 6 Feet).
Check Stock

Steinel HG2220E Electronic Thermocouple Heat Gun

  • 1500 W Heat Gun with variable temperature between 120°F - 1100°F, 3 Stage Air Contro and Duratherm heating element.
  • Thermocouple control for precise temperature regulation.
  • The Heating Tool is well suited for plastic welding, packaging, automotive, maintenance.
  • Double insulated Power Tool with an ergonomically designed shape and a 6 ft long Power-Cord.
  • Reduction nozzles are approved for use on Professional Heat Guns with electronic thermocouple control.
Check Stock

REED Instruments R2800 Temperature Simulator (Thermocouple and RTD)

  • Source 8 thermocouple types, including R, S, B, E, K, J, T, N.
  • and 7 RTD types, including Pt 10 (385), Pt100 (385), Pt200 (385), Pt500 (385), Pt1000 (385), Cu10, Cu50.
  • Includes test leads, alligator clips, thermocouple adapter, protective holster and batteries.
Check Stock

General Tools IRT659K Infrared Thermometer K Type Thermocouple 12 1

  • Infrared thermometer measurement range is -58 to 1202 degrees Fahrenheit (-50 to 650 degrees Celsius).
  • K type thermocouple measurement range is -146 to 2498 degrees Fahrenheit (-99 to 1370 degrees Celsius).
  • Thermometer measure is K-type thermocouple with 0 to 500 degrees F (-18 to 260 degrees C) range.
  • Digital thermometer automatically stores last 10 readings for recall.
Check Stock

PIE 525B Automated T/C & RTD Calibrator 12 RTD & 14 T/C types

  • Automated RTD and Thermocouple Calibrator. Comes with rubber boot, hands free carrying case, test leads and NIST cert..
  • Easy to use With the PIE 525B you can check and calibrate all your thermocouple and RTD instruments and measure temperature sensors..
  • Take it into the shop, plant or field Carry it without worry - it comes protected with a rubber boot and rugged, low profile switches. Easy to operate even in the dark areas of the plant with the backlit display..
  • Calibrate thermocouple instruments to 0.1 & 0.01 degrees-F & degrees-C The PIE 525B works with the thermocouples you use including types J, K, T, E, R, S, B, N, G, C, D, L (J-DIN), U (T-DIN) and P (Platinel II). Or calibrate from -13.0000 to +80.0000 mV..
  • Calibrate RTD instruments to 0.1 & 0.01 degrees-F & degrees-C Stop carrying around a decade box and RTD resistance tables. The 525B works with the RTDs you use including Platinum 10, 50, 100, 200, 500 & 1000 Ohm (alpha = 3850), Platinum 100 Ohm (alpha = 3902, 3916, 3926), Copper 10 & 50 Ohm, and Nickel 120 Ohm. Or calibrate from 0.000 to 400.000 and 0.00 to 4000.00 Ohms..
Check Stock