Automated RTD and Thermocouple Calibrator. Comes with rubber boot, hands free carrying case, test leads and NIST cert..
Easy to use With the PIE 525B you can check and calibrate all your thermocouple and RTD instruments and measure temperature sensors..
Take it into the shop, plant or field Carry it without worry - it comes protected with a rubber boot and rugged, low profile switches. Easy to operate even in the dark areas of the plant with the backlit display..
Calibrate thermocouple instruments to 0.1 & 0.01 degrees-F & degrees-C The PIE 525B works with the thermocouples you use including types J, K, T, E, R, S, B, N, G, C, D, L (J-DIN), U (T-DIN) and P (Platinel II). Or calibrate from -13.0000 to +80.0000 mV..
Calibrate RTD instruments to 0.1 & 0.01 degrees-F & degrees-C Stop carrying around a decade box and RTD resistance tables. The 525B works with the RTDs you use including Platinum 10, 50, 100, 200, 500 & 1000 Ohm (alpha = 3850), Platinum 100 Ohm (alpha = 3902, 3916, 3926), Copper 10 & 50 Ohm, and Nickel 120 Ohm. Or calibrate from 0.000 to 400.000 and 0.00 to 4000.00 Ohms..
Dry Block High Temperature Calibrator Range 50 to 650°C with Thermocouples T J K N R S for Calibration Labs Pharmaceutical Divisions Thermal Plants Metallurgical Plants Model AI-DBC-02
Accuracy: ±0.025% of Reading + 0.25 mV | Volts Range: 0 to 10.000 V.
Accuracy: ±0.025% of Reading + 3 mV | Ohms Range: 0 to 400 Ohms.
Accuracy: ±0.025% of Reading + 0.1 Ohm | RTD3 Range: -200 to 8500 C.
Thermocouple Types: T, J, K, N, R, S | Thermocouple Range( T,J,K,R,S): -200 to 400°C.
Accuracy: ±0.025 % of Reading + 1°C |Thermocouple Range(R,S): 300 to 1760°C.
Supply Scope: 1 Unit of DBC-02 Dry Block Calibrator, Power Cable, 1 Unit of Test Lead (2 Wire), Insertion Tube: Dual Hole - 1 x 1/4” + 1 x 12.5 mm, Dual Hole - 1 x 1/4” + 1 x 8.2 mm, 1 Unit of Insertion Tool, 2no.s of 6A Spare Fuses, Instruction Manual and Factory Calibration Certificate | Applications: Calibration Labs, Pharmaceutical Divisions, Thermal Plants, Metallurgical Plants.
Portable, dual-input thermometer for reading temperatures from two sources simultaneously, and is used in quality control and HVAC, electrical, industrial, and automotive maintenance.
Dual-scale temperature readings range from -328 to 2,498 degrees F (-200 to 1,370 degrees C).
Dual-input thermocouples for superheat and subcool applications, and cut-out and cut-in temperature measurements, and offset mode compensates for thermocouple error.
Backlit LCD screen with a data hold feature to save temperature readings for later viewing, maximum and minimum temperature with elapsed time, average and relative temperature calculations, and low battery indicator.