Voltage Monitoring Relay Protection 3-Phase AC 220-440V Small Size Phase Sequence Protection Phase Sequence Relay for Industry Applications
Dynamic phase loss, static phase loss protection: refers to the phase failure of any phase when the protected device is in the running state or non-operating state. The indicator light is in the form of red light and priority.
Wrong phase protection: A protection measure to prevent the phase sequence of L1, L2, L3 three-phase AC power supply from being connected incorrectly. Instant action. The indicator light is in the form of yellow light..
Voltage Unbalance Protection: Refers to a voltage imbalance that will affect the safe operation of the device. When the voltage imbalance rate is higher than 8%. The form of the indicator light is: the lack of phase red light is on, and priority..
Delay protection: When there is a fault, the monitor will delay after 1~2 seconds, and the relay will release..
The protection function of the monitor is not affected by the current of the line or load, the inrush current, the unbalanced current and the nature of the load. Long-term work with full performance and full climate. Power consumption is no more than 2W..
TG30S Mini AC 220-440V Voltage Monitoring Relay Phase Sequence Protection Protection 3-Phase Phase Sequence Relay for Industry Applications
Dynamic phase loss, static phase loss protection: refers to the phase failure of any phase when the protected device is in the running state or non-operating state. The indicator light is in the form of red light and priority.
Wrong phase protection: A protection measure to prevent the phase sequence of L1, L2, L3 three-phase AC power supply from being connected incorrectly. Instant action. The indicator light is in the form of yellow light..
Voltage Unbalance Protection: Refers to a voltage imbalance that will affect the safe operation of the device. When the voltage imbalance rate is higher than 8%. The form of the indicator light is: the lack of phase red light is on, and priority..
Delay protection: When there is a fault, the monitor will delay after 1~2 seconds, and the relay will release..
The protection function of the monitor is not affected by the current of the line or load, the inrush current, the unbalanced current and the nature of the load. Long-term work with full performance and full climate. Power consumption is no more than 2W..
...group pre-amp input), a Headphone amplifier and this is a amplifier for Phono player too, direct link your phono player to this amplifier to output to speakers..
Pure Handmade,point to point hand welding using two high-quality wide-frequency high-quality Japanese EI output transformer using a high-power Z11 core toroidal power transformer dedicated designed for the machine , voltage amplification and promote are used tube 5AR4 for rectifier power supply..
Use 12AX7 and 12AU7 vacuum tube for voltage amplification and phase inversion,use KT88 vacuum tube to do AB1 push-pull power amplification.
Mute delay function when turn on the amp(about 30 seconds) ;the choice of Japanese ALPS motor potentiometer.
Provide Triode and Ultralinear selection function: Triode work mode. soft. pure and sleek. suitable for enjoying vocals. strings Music and other types of music.
Ultralinear work. the sound of open. unrestrained. the momentum is good. for large scenes. large dynamic type of music. Peripheral power tube current adjustment knob and current display meter. With pure power amplifier features. can be linked the pre-amp signal input....
Mini AC 220-440V TG30S Phase Sequence Protection Voltage Monitoring Relay Voltage Phase Protective Relay Building Electronics Projects for Industry Applications
Dynamic phase loss, static phase loss protection: refers to the phase failure of any phase when the protected device is in the running state or non-operating state. The indicator light is in the form of red light and priority.
Wrong phase protection: A protection measure to prevent the phase sequence of L1, L2, L3 three-phase AC power supply from being connected incorrectly. Instant action. The indicator light is in the form of yellow light..
Voltage Unbalance Protection: Refers to a voltage imbalance that will affect the safe operation of the device. When the voltage imbalance rate is higher than 8%. The form of the indicator light is: the lack of phase red light is on, and priority..
Delay protection: When there is a fault, the monitor will delay after 1~2 seconds, and the relay will release..
The protection function of the monitor is not affected by the current of the line or load, the inrush current, the unbalanced current and the nature of the load. Long-term work with full performance and full climate. Power consumption is no more than 2W..
VFD 220V 0.75KW 1hp Variable Frequency Drive CNC VFD Motor Drive Inverter Converter for Spindle Motor Speed Control HUANYANG HY-Series(0.75KW, 220V)
IMPORTANT NOTE: this VFD is applicable to THREE phase motor and NOT support external resistor.Fan runs all the time even though the motor isn't (fan functions need to be customized)..
This drive is very suitable for HIGH-SPEED ROTATION motors,such as spindle motor, engraving machine CNC.Work with 220V single phase input and 220V three phase input.you can just connected L1/L2 to any two of VFD input R/S/T.
This VFD can be used for constant torque loads (such as hard starting: Air compressors, HVAC units) and variable torque loads (such as pumps, fans, etc). It can be used as a motor speed control and a phase converter.This item use Sine wave PWN(SPWM) for the control system.It is designed which also could use USA 60hz single phase input.Can work well with the Mach 3 controller.
Application: Spindle motor.CNC router, CNC machine, milling machine, drilling machine, wingding machine, mixer, extruder, slitter, winder, compressor, ventilator, pump, grinder, conveyor, elevator, centrifuger and other speed control machines.
If there are problems in use after you receive,please don't give us negative or natural feedback.Please contact us as soon as possible, we will help you solve problems or help you replace new one ..
... This is also a Power Amplifier (there is a group pre-amp input), a Headphone amplifier and this is a amplifier for Phono player too, direct link your phono player to this amplifier to output to speakers..
Pure Handmade,point to point hand welding using two high-quality wide-frequency high-quality Japanese EI output transformer using a high-power Z11 core toroidal power transformer dedicated designed for the machine , voltage amplification and promote are used tube 5AR4 for rectifier power supply..
Use 12AX7 and 12AU7 vacuum tube for voltage amplification and phase inversion,use KT88 vacuum tube to do AB1 push-pull power amplification.
Mute delay function when turn on the amp(about 30 seconds) ;the choice of Japanese ALPS motor potentiometer.
Provide Triode and Ultralinear selection function: Triode work mode. soft. pure and sleek. suitable for enjoying vocals. strings Music and other types of music.
Ultralinear work. the sound of open. unrestrained. the momentum is good. for large scenes. large dynamic type of music. Peripheral power tube current adjustment knob and current display meter. With pure power amplifier features. can be linked the pre-amp signal input. with the phono function. can be connected to the Phono player.